dc.identifier.citationAdiyabazar, C., Gonzalez-Longatt, F., Acosta, M. N., Rueda, J. L., & Palensky, P. (2020, October 26-28). Optimal UFLS Settings: An Assessment of Frequency System Response Indicators. I 2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe) (p. 1141-1145).en_US
dc.identifier.isbn978-1-7281-7100-5
dc.identifier.urihttps://hdl.handle.net/11250/2756985
dc.description.abstractThis paper investigates the positive changes in the system frequency response indicators caused by the implementation of a set of optimal settings of an under-frequency load shedding (UFLS) scheme. The optimal UFLS scheme is optimised by minimising the total amount of load shedding and considering the recovery process of the system frequency into its operational values after several losses of generation and satisfies the requirements of the UFLS standard (PRC-006-SERC-02). The idea of implementing the optimal UFLS scheme is to identify how changes the minimum frequency, minimum time, rate of change of frequency and steady-state frequency when the amount of load shedding change. The optimal UFLS scheme formulation starts with identifying the variables to control with the optimisation and its respective bounds. Then, the objective function is formulated in terms of the total load shedding, and finally, the restrictions and requirements of the systems are written as inequality constraints. The optimal UFLS is evaluated in the IEEE 39-bus system. The simulations results demonstrate the suitability of the optimal UFLS to improve the frequency response indicators.en_US
dc.language.isoengen_US
dc.relation.ispartof2020 IEEE PES Innovative Smart Grid Technologies Europe - ISGT-Europe
dc.titleOptimal UFLS Settings: An Assessment of Frequency System Response Indicatorsen_US
dc.typeChapteren_US
dc.description.versionacceptedVersionen_US
dc.rights.holder© 2020 IEEE.en_US
dc.source.pagenumber1141-1145en_US
dc.identifier.doihttps://doi.org/10.1109/ISGTEurope47291.2020.9248760