Vis enkel innførsel

dc.contributor.authorRahlf, Anna Lina
dc.contributor.authorPetersen, Evi
dc.contributor.authorRehwinkel, Dominique
dc.contributor.authorZech, Astrid
dc.contributor.authorHamacher, Daniel
dc.date.accessioned2020-03-17T09:25:19Z
dc.date.available2020-03-17T09:25:19Z
dc.date.created2019-10-29T13:48:38Z
dc.date.issued2019
dc.identifier.citationFrontiers in Sports and Active Living. 2019, (September), .en_US
dc.identifier.issn2624-9367
dc.identifier.urihttps://hdl.handle.net/11250/2647110
dc.descriptionThis is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.en_US
dc.description.abstractDiminishing proprioception caused by aging effects is associated with a higher risk to fall. However, existing measurement systems of proprioception are often expensive, time-consuming, or insufficient regarding reliability evaluation. Inertial sensor-based systems could address these issues. Consequently, this study sought to develop and evaluate an inertial sensor-based joint position sense test. Thereto, intra-session and inter-day test-retest reliability were investigated in a cross-over design. Twenty healthy younger (age: 22 ± 3 years) and 20 healthy older adults (age: 65 ± 5 years) participated in the study. We calculated the mean of the absolute error, the signed error, and the standard deviation of the signed error. Test-retest reliability was quantified by using the intraclass correlation coefficient as well as the bias and limits of agreement. To evaluate the possibility of capturing aging effects, and correspondingly a validation of the system, we calculated Cohen's d. For the intra-session reliability, fair to good agreements were achieved for the absolute and relative error in all target ranges. Compared to younger adults, we registered a declined joint position sense in older adults with high effects observed for the absolute error in a target range of 15–25 and 35–45° as well as for the variable error in the target ranges of 35–45 and 55–65°. We suggest that inertial sensor-based joint position sense tests are reliable and capable to measure aging effects on proprioception, and are therefore a low-cost and mobile alternative to existing methods.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleValidity and Reliability of an Inertial Sensor-Based Knee Proprioception Test in Younger vs. Older Adultsen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2019 Rahlf, Petersen, Rehwinkel, Zech and Hamacher.en_US
dc.source.pagenumber6en_US
dc.source.journalFrontiers in Sports and Active Livingen_US
dc.source.issueSeptemberen_US
dc.identifier.doi10.3389/fspor.2019.00027
dc.identifier.cristin1741702
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal