Show simple item record

dc.contributor.authorSøpstad, Sindre
dc.contributor.authorImenes, Kristin
dc.contributor.authorJohannessen, Erik Andrew
dc.date.accessioned2020-02-13T08:24:15Z
dc.date.available2020-02-13T08:24:15Z
dc.date.created2020-01-09T09:55:13Z
dc.date.issued2019
dc.identifier.citationBiosensors & bioelectronics. 2019, 130, 374-381.en_US
dc.identifier.issn0956-5663
dc.identifier.urihttps://hdl.handle.net/11250/2641455
dc.descriptionThis article has been accepted for publication and undergone full peer review but has not been through the copyediting, typesetting, pagination and proofreading process, which may lead to differences between this version and the Version of Record.en_US
dc.description.abstractA small, standalone electrochemical hybrid sensor platform, combining flexible electronics and screen-printed electrodes, is demonstrated in the determination of capsaicin through adsorptive stripping voltammetry. The sensing scheme was simplified to be compatible with a low-cost device. The simplification involved eliminating the need for additional modification of the electrode and employing a coarsely stepped squarewave voltammetry, a technique which is applicable with less sophisticated instrumentation. This architecture was found to be suitable for concentrations up to at least 5000 µM with a detection limit of 1.98 µM. The screen-printed carbon graphite electrodes were made reusable through an ethanol rinsing protocol. The effect of ethanol/buffer volumetric ratio in the test sample was shown to greatly influence the analytical data, and a fixed 10% (v/v) was chosen as a compromise between signal-to-noise ratio and not exceeding the solubility limit of the desired upper range.en_US
dc.language.isoengen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/deed.no*
dc.titleHybrid electrochemical sensor platform for capsaicin determination using coarsely stepped cyclic squarewave voltammetryen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionacceptedVersionen_US
dc.source.pagenumber374-381en_US
dc.source.volume130en_US
dc.source.journalBiosensors & bioelectronicsen_US
dc.identifier.doihttps://doi.org/10.1016/j.bios.2018.09.036
dc.identifier.cristin1769016
dc.relation.projectNorges forskningsråd: 245963 (NORFAB)en_US
cristin.unitcode222,58,4,0
cristin.unitnameInstitutt for mikrosystemer
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internasjonal