The use of 80 kV versus 100 kV in pulmonary CT angiography: An evaluation of the impact on radiation dose and image quality on two CT scanners

Rusandu, Albertina; Ødegård, Asbjørn; Engh, Gabriele; Olerud, Hilde M
Journal article, Peer reviewed
Accepted version
Thumbnail
View/Open
LOCKED_UNTIL20191109_2018OlerudUse (495.9Kb)
URI
http://hdl.handle.net/11250/2588548
Date
2018
Metadata
Show full item record
Collections
  • Fakultetet for helse- og sosialvitenskap [16]
  • Institutt for optometri, radiografi og lysdesign [75]
  • Publikasjoner fra CRIStin [1792]
Original version
Radiography.2018, 25(1), 58-64.   https://doi.org/10.1016/j.radi.2018.10.004
Abstract
Introduction

Use of CT in the investigation of pulmonary embolism in radiosensitive patients such as pregnant and young female patients entails the need for protocol optimization. The aim of this study was to analyze the dose reduction and image quality achieved by using 80 kV instead of 100 kV in CT pulmonary angiography protocols.

Methods

80 examinations of non-obese patients were analyzed (40 consecutive patients for each protocol, equally distributed on two CT scanners). Objective image quality was assessed by measurements of HU values (average and standard deviation) in five ROIs in pulmonary arteries and calculations of signal-to-noise (SNR) and contrast-to-noise ratios (CNR). Subjective image quality was independently evaluated by two radiologists in terms of perceived noise, sharp reproduction of pulmonary arteries and overall diagnostic quality. Radiation dose parameters (CTDIvol, DLP, SSDE and effective dose) and effective risk were compared. Differences in radiation dose and objective measures of image quality for the two protocols were assessed using the independent t test; comparison of subjective grading of image quality was performed with the Mann–Whitney U test.

Results

Use of 80 kV significantly increased both arterial contrast enhancement and image noise. Differences in SNR and CNR between protocols were not statistically significant. Achieved dose reduction by using 80 kV was significant on both scanners (SSDE reduction 35% and 46%, p < 0.001; effective dose reduction 40% and 53%, p < 0.001).

Conclusion

Use of 80 kV protocols for CT examinations of pulmonary arteries in non-obese patients with bodyweight below 80 kg results in significant reduction of radiation doses without compromising image quality.
Journal
Radiography

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit
 

 

Browse

ArchiveCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsDocument TypesJournalsThis CollectionBy Issue DateAuthorsTitlesSubjectsDocument TypesJournals

My Account

Login

Statistics

View Usage Statistics

Contact Us | Send Feedback

Privacy policy
DSpace software copyright © 2002-2019  DuraSpace

Service from  Unit