Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975-2021
Afroz, Susmita; Østerås, Bjørn Helge; Thevathas, Utheya Salini; Meo, Malgorzata Sitek; Jahnen, Andreas; Dabin, Jérémie; Thierry-Chef, Isabelle; Robsahm, Trude Eid; Døhlen, Gaute; Olerud, Hilde Merete
Peer reviewed, Journal article
Published version

View/ Open
Date
2024Metadata
Show full item recordCollections
Original version
Afroz, S., Østerås, B. H., Thevethas, U. S., Meo, M., Jahnen, A., Dabin, J., ... & Olerud, H. M. (2024). Doses from ionising radiation in paediatric cardiac catheterisations in Norway 1975–2021. Journal of Radiological Protection, 44(4), Artikkel 041513. https://doi.org/10.1088/1361-6498/ad958eAbstract
Paediatric patients with congenital heart disease often undergo cardiac catheterisation procedures and are exposed to considerable ionising radiation early in life. This study aimed to develop a method for estimating the dose area product (PKA) from paediatric cardiac catheterisation procedures (1975–1989) at a national centre for paediatric cardiology and to evaluate trends in PKA and exposure parameters until 2021. Data from 2200 catheterisation procedures on 1685 patients (1975–1989) and 4184 procedures on 2139 patients (2000–2021) under 18 years of age were retrospectively collected. PKA values were missing for 1975–1989 but available from 2000 onward. The missing PKA was estimated from air kerma and beam area, based on exposure records and input from clinicians working at that time. PKA trends were analysed over time and age. There was a 71% reduction in median PKA from the period 1975–1989 (median 6.63 Gy cm2) to 2011–2021 (1.91 Gy cm2). The PKA increases significantly (p = 0.0001) with patient age, which was associated with body weight. Approximately 80% of the total PKA was from cine acquisition in 1975–1989, while 20% was from fluoroscopy. The PKA estimate during 1975–1989 was considerably impacted by the assumptions of missing parameters such as tube filtration, focus-to-heart distance, beam area, and number of cine series. The decreasing trend in PKA values was attributed to advancements in both technologies and clinical practices. The high contribution of cine acquisition to the total dose during 1975–1989 was due to factors such as a high frame rate, multiple acquisitions, and high tube current. The estimated PKA values for the period 1975–1989 are of importance for the dose reconstruction and risk assessments in the EU epidemiology project Health Effects of Cardiac Fluoroscopy and Modern Radiotherapy in Pediatrics(HARMONIC).