Vis enkel innførsel

dc.contributor.authorXia, Hexin
dc.contributor.authorAkram, Muhammad Nadeem
dc.contributor.authorBardalen, Eivind
dc.contributor.authorRoy, Avisek
dc.contributor.authorAasmundtveit, Knut
dc.contributor.authorØhlckers, Per
dc.date.accessioned2021-06-08T13:45:01Z
dc.date.available2021-06-08T13:45:01Z
dc.date.created2020-12-31T14:47:36Z
dc.date.issued2020
dc.identifier.citationXia, H., Akram, M. N., Bardalen, E., Roy, A., Aasmundtveit, K. E., & Ohlckers, P. (2020, September 15-18). Evaluation of Silicon Diaphragms for Hermetic Packaging of Microbolometer Arrays. In K. Aasmundtveit, K. Imenes & P. M. Svasta (Eds.), 2020 IEEE 8th Electronics System-Integration Technology Conference (ESTC) (pp. 1-5). IEEE.en_US
dc.identifier.isbn978-1-7281-6293-5
dc.identifier.urihttps://hdl.handle.net/11250/2758542
dc.description.abstractHermetic packaging is a critical requirement for microbolometers to maintain long-term reliability. A thinner diaphragm is desirable for vacuum packaging of microbolometers to obtain higher infrared light transmission. However, a thinner diaphragm results in a larger deflection due to the pressure difference from atmosphere, which may influence the IR signal focus and possibly cause mechanical failure. In this paper, the trade-offs of using thin single crystal silicon diaphragms as encapsulation for hermetic packaging of microbolometer arrays have been investigated in terms of the mechanical stability and optical performance using COMSOL and Zemax. The optical simulations show that the bending of the thin diaphragm has negligible effect on the infrared light focus with wavelengths from 8 to 14 μm. The mechanical simulations reveal that a thin diaphragm (thickness <; 70 μm) with 10×10 mm 2 area and a diaphragm (thickness <; 90 μm) with 12×12 mm 2 area will cause mechanical failure, and the designed diaphragm thickness must incorporate margins to these values.en_US
dc.language.isoengen_US
dc.relation.ispartof2020 IEEE 8th Electronics System-Integration Technology Conference (ESTC)
dc.titleEvaluation of Silicon Diaphragms for Hermetic Packaging of Microbolometer Arraysen_US
dc.typeChapteren_US
dc.description.versionsubmittedVersionen_US
dc.rights.holder© 2020 IEEE.en_US
dc.source.pagenumber5en_US
dc.identifier.doihttps://doi.org/10.1109/ESTC48849.2020.9229710