Vis enkel innførsel

dc.contributor.authorTørhaug, Tom
dc.contributor.authorBrurok, Berit
dc.contributor.authorHoff, Jan
dc.contributor.authorHelgerud, Jan
dc.contributor.authorLeivseth, Gunnar
dc.date.accessioned2020-09-24T12:58:23Z
dc.date.available2020-09-24T12:58:23Z
dc.date.issued2016
dc.identifier.citationTørhaug, T., Brurok, B., Hoff, J., Helgerud, J., & Leivseth, G. (2016). Arm Crank and Wheelchair Ergometry Produce Similar Peak Oxygen Uptake but Different Work Economy Values in Individuals with Spinal Cord Injury. BioMed Research International, 2016, 5481843.en_US
dc.identifier.issn2314-6141
dc.identifier.urihttps://hdl.handle.net/11250/2679510
dc.description.abstractObjective. To study whether values for peak oxygen uptake (VO2peak) and work economy (WE) at a standardized workload are different when tested by arm crank ergometry (ACE) and wheelchair ergometry (WCE). Methods. Twelve paraplegic men with spinal cord injury (SCI) in stable neurological condition participated in this cross-sectional repeated-measures study. We determined VO2peak and peak power output (POpeak) values during ACE and WCE in a work-matched protocol. Work economy was tested at a standardized workload of 30Watts (W) for both ACE and WCE. Results. There were no significant differences in VO2peak (mL⋅kg−1 ⋅min−1) between ACE (27.3 ± 3.2) andWCE (27.4 ± 3.8) trials, and a Bland-Altman plot shows that findings are within 95% level of agreement. WE or oxygen consumption at 30W (VO2-30W) was significantly lower during WCE compared to ACE (𝑃�� < 0.039). Mean (95% CI) POpeak (W) were 130 (111–138) and 100 (83–110) during ACE andWCE, respectively. Conclusion. The findings in the present study support the use of both ACE and WCE for testing peak oxygen uptake. However, WE differed between the two testmodalities, meaning that less total energy is used to performexternal work of 30Wduring wheelchair exercise when using thisWCE (VP100 Handisport ergometer). Clinical Trials Protocol Record is NCT00987155/4.2007.2271.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 3.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/deed.no*
dc.titleArm crank and wheelchair ergometry produce similar peak oxygen uptake but different work economy values in individuals with spinal cord injuryen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holderCopyright © 2016 Tom Tørhaug et al.This is an open access article distributed under the Creative Commons Attribution License,en_US
dc.source.journalBioMed Research Internationalen_US
dc.identifier.doihttps://doi.org/10.1155/2016/5481843
dc.identifier.cristin1362017


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 3.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 3.0 Internasjonal