Vis enkel innførsel

dc.contributor.authorNguyen, Hoang-Vu
dc.contributor.authorKristiansen, Helge
dc.contributor.authorLifjeld, Anders
dc.contributor.authorImenes, Kristin
dc.contributor.authorAasmundtveit, Knut
dc.date.accessioned2020-03-19T12:13:58Z
dc.date.available2020-03-19T12:13:58Z
dc.date.created2020-03-11T12:07:08Z
dc.date.issued2019
dc.identifier.isbn978-0-9568086-6-0
dc.identifier.urihttps://hdl.handle.net/11250/2647562
dc.descriptionThis is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.en_US
dc.description.abstractReworkable anisotropic conductive adhesives (ACAs) are of interest when the material is used for the assembly of electronic modules with high value, such as in medical ultrasound probes. Commercially available ACAs are generally difficult or even impossible to rework due to the common use of thermosetting adhesive matrix. ACA material with competitive performance compared to conventional ACAs and with reworkability at modest conditions is developed in this work. Adhesive matrices comprising a blend of a thermosetting epoxy and a thermoplastic polymer are selected because it has shown potential to ensure good electrical and mechanical integrity whilst still allowing reworkablity for ACA interconnects. This paper presents the findings of favourable mixing ratios between an epoxy system compatible with ACA applications and a high-performance thermoplastic polymer that offer good mechanical strength combined with reworkability. Die shear strength at varying temperatures relevant for production/storage (23 °C), operation of medical ultrasound probes (50 °C) and rework of ACA bonds (190 °C) is studied. Complete removal of adhesive remaining on bonding surfaces, for successful rework, is verified. The results show a high die shear strength at both 23 °C and 50 °C for adhesive formulations comprising up to 67 wt% of thermoplastic polymer, being comparable to the shear strength obtained for common lead-free solders and conventional ACAs. The die shear strength at 190 °C drops dramatically, and agrees very well with the results from the rework evaluation.en_US
dc.language.isoengen_US
dc.relation.ispartof2019 22nd European Microelectronics and Packaging Conference & Exhibition (EMPC)
dc.titleReworkable Anisotropic Conductive Adhesive for Assembly of Medical Devicesen_US
dc.typeChapteren_US
dc.description.versionacceptedVersionen_US
dc.rights.holder© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.en_US
dc.identifier.doi10.23919/EMPC44848.2019.8951801
dc.identifier.cristin1801131
dc.relation.projectNorges forskningsråd: 269618en_US
dc.relation.projectNorges forskningsråd: 245963en_US
cristin.ispublishedtrue
cristin.fulltextpreprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel