Show simple item record

dc.contributor.authorDupre, Antoine
dc.contributor.authorMylvaganam, Kanagasabapath
dc.date.accessioned2019-01-16T13:50:10Z
dc.date.available2019-01-16T13:50:10Z
dc.date.created2018-10-01T14:14:55Z
dc.date.issued2018
dc.identifier.citationSensors. 2018, 18 (4), 1-14.nb_NO
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/11250/2580947
dc.descriptionThis article is an open access article distributed under the terms and conditions of the Creative Commons Attributionnb_NO
dc.description.abstractThis paper presents a concept for soft field tomographic scan of all the projections of electromagnetic waves emanating from an array of electrodes. Instead of the sequential excitation of all pairs of electrodes in the list of all projections, the new method present here consists of a single and continuous excitation. This excitation signal is the linear combination of the excitation signals in the projection set at different AC frequencies. The response to a given projection is discriminated by selecting the corresponding AC frequency component in the signal spectra of the digitally demodulated signals. The main advantage of this method is the suppression of transients after each projection, which is particularly problematic in electrical impedance tomography due to contact impedance phenomena and skin effect. The second benefit over the sequential scan method is the increased number of samples for each measurement for reduced noise sensitivity with digital demodulation. The third benefit is the increased temporal resolution in high-speed applications. The main drawback is the increased number of signal sources required (one per electrode). This paper focuses on electrical impedance tomography, based on earlier work by the authors. An experimental proof-of-concept using a simple 4-electrodes electrical impedance tomographic system is presented using simulations and laboratory data. The method presented here may be extended to other modalities (ultrasonic, microwave, optical, etc.).nb_NO
dc.description.abstractA Simultaneous and Continuous Excitation Method for High-Speed Electrical Impedance Tomography with Reduced Transients and Noise Sensitivity.nb_NO
dc.language.isoengnb_NO
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleA Simultaneous and Continuous Excitation Method for High-Speed Electrical Impedance Tomography with Reduced Transients and Noise Sensitivity.nb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.rights.holder© 2018 by the authors. Licensee MDPI, Basel, Switzerland.nb_NO
dc.source.pagenumber1-14nb_NO
dc.source.volume18nb_NO
dc.source.journalSensorsnb_NO
dc.source.issue4nb_NO
dc.identifier.doi10.3390/s18041013
dc.identifier.cristin1616809
cristin.unitcode222,58,2,0
cristin.unitnameInstitutt for elektro, IT og kybernetikk
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal