Vis enkel innførsel

dc.contributor.authorRautenbach, Christo
dc.contributor.authorMelaaen, Morten Christian
dc.contributor.authorHalvorsen, Britt
dc.date.accessioned2013-03-16T11:54:21Z
dc.date.accessioned2017-04-19T12:52:25Z
dc.date.available2013-03-16T11:54:21Z
dc.date.available2017-04-19T12:52:25Z
dc.date.issued2012
dc.identifier.citationRautenbach, C., Melaaen, M.C & Halvorsen, B.M. (2013). Statistical diagnosis of a gas-solid fluidized bed using Electrical Capacitance Tomography. International Journal of Multiphase Flow 49, 70-77I
dc.identifier.issn1879-3533
dc.identifier.urihttp://hdl.handle.net/11250/2438524
dc.description.abstractFluidization experiments were performed using several particle size distributions of spherical glass particles, ranging from Geldart B to D. An Electrical Capacitance Tomography (ECT) tomograph was utilised in the present study and its usefulness as a diagnostic tool is illustrated. During the experiments a 10.4cm diameter tower was utilised and the tower was operated at atmospheric pressure and room temperature (cold fluidized bed). Statistical analysis were performed on the average solid fraction data obtained using the ECT tomograph. Using the time domain skewness and kurtosis the time series could be characterised and the quality of fluidization is determined at different superficial gas velocities (Azizpour, H., Sotudeh-Gharebagh, R., Zarghami, R., Abbasi, M., Mostoufi, N., and Mahjoob, M. (2011). Characterization of gas-solid fluidized bed hydrodynamics by vibration signal analysis. International Journal of Multiphase Flow, 37:788-793). Statistical analysis is also used to characterise the influence of small particles on the bed hydrodynamics.
dc.language.isoeng
dc.relation.ispartofRautenbach, C. An Experimental and Theoretical Study of Dense Fluidized Bed Fluid Dynamics. PhD Thesis, Telemark University College, 2012
dc.relation.ispartofhttp://hdl.handle.net/2282/1223
dc.subjectECT
dc.subjectgas-solid fluidization
dc.subjectparticle size distribution
dc.subjectfluidization quality
dc.subjectskewness
dc.subjectexcess kurtosis
dc.titleStatistical diagnosis of a gas-solid fluidized bed using Electrical Capacitance Tomography
dc.typeJournal article
dc.typePeer reviewed
dc.description.versionSubmitted version
dc.rights.holderCopyright Elsevier. All rights reserved.
dc.subject.nsi562
dc.subject.nsi610
dc.identifier.doihttp://dx.doi.org/10.1016/j.ijmultiphaseflow.2012.10.002


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel