Vis enkel innførsel

dc.contributor.authorRautenbach, Christo
dc.contributor.authorMudde, Robert F.
dc.contributor.authorYang, X.
dc.contributor.authorMelaaen, Morten Christian
dc.contributor.authorHalvorsen, Britt
dc.date.accessioned2013-03-16T11:43:13Z
dc.date.accessioned2017-04-19T12:52:21Z
dc.date.available2013-03-16T11:43:13Z
dc.date.available2017-04-19T12:52:21Z
dc.date.issued2013
dc.identifier.citationRautenbach, C., Mudde, R.F., Yang, X., Melaaen, M.C & Halvorsen, B.M. (2013). A comparative study between Electrical Capacitance Tomography and Time-resolved X-ray tomography. Flow Measurement and Instrumentation 30, 34-44.
dc.identifier.issn0955-5986
dc.identifier.urihttp://hdl.handle.net/11250/2438516
dc.description.abstractModern day tomographs enable the research community to investigate the internal flow behaviour of a fluidized bed by non invasive methods that partially overcome the opaque nature of a dense bubbling bed. Each tomographic modality has its own limitations and advantages and in the present study two modern day tomographic systems were evaluated with respect to their performance on a cold dense fluidized bed. The two tomographs investigated are an Electrical Capacitance Tomography (ECT) tomograph and a time-resolved X-ray tomography tomograph. The study was performed on spherical glass particles with various particle size distributions that could mainly be classified as Geldart B or D particles. Two experimental towers were employed, one with a diameter of 10.4cm and the other 23.8cm while compressed air was used as fluidizing fluid during all of the experiments. Results obtained with both systems are provided in comprehensive figures and tables and some first results are obtained with the time-resolved X-ray tomography system. The bubble size measurements of both tomographs are compared with several theoretical correlations via the root mean square error of the predictions (RMSEP). With the results it was also concluded that a small amount of small particles can noticeably alter the fluidization hydrodynamics of a powder. The bubble frequencies are also presented to aid in understanding the hydrodynamic behaviour of the powders investigated. A comprehensive summary of the two tomographic modalities is also provided.
dc.language.isoeng
dc.relation.ispartofRautenbach, C. An Experimental and Theoretical Study of Dense Fluidized Bed Fluid Dynamics. PhD Thesis, Telemark University College, 2012
dc.relation.ispartofhttp://hdl.handle.net/2282/1223
dc.subjectbubbles size
dc.subjectfluidization
dc.subjectcomparative study
dc.subjectelectrical Capacitance Tomography (ECT)
dc.subjectx-ray tomography
dc.titleA comparative study between electrical capacitance tomography and time-resolved X-ray tomography
dc.typeJournal article
dc.typePeer reviewed
dc.description.versionSubmitted version
dc.rights.holderCopyright Elsevier. All rights reserved.
dc.subject.nsi562
dc.subject.nsi610
dc.identifier.doihttp://dx.doi.org/10.1016/j.flowmeasinst.2012.11.005