Vis enkel innførsel

dc.contributor.authorLundanes, Eilin
dc.contributor.authorGustafsson, Jörgen
dc.date.accessioned2022-10-18T13:28:46Z
dc.date.available2022-10-18T13:28:46Z
dc.date.created2022-02-24T13:51:44Z
dc.date.issued2020
dc.identifier.citationLundanes, E., & Gustafsson, J. (2020). Refitting a patient with pellucid marginal degeneration from a corneal rigid gas permeable lens to scleral lens. Scandinavian Journal of Optometry and Visual Science, 13(1), 19–23.en_US
dc.identifier.issn1891-0882
dc.identifier.urihttps://hdl.handle.net/11250/3026725
dc.description.abstractThis case report describes a 66 years old male patient with pellucid marginal degeneration (PMD). The patient had fallen out of a regular follow-up scheme and presented with a poorly fitting corneal rigid lens that he had worn for almost five years. Correction had failed to improve vision in the left eye, so the patient wears a contact lens in his right eye only. Scleral lenses vault over the cornea, the tear layer between the lens and the cornea masks corneal irregularities and are a good correction option for corneal ectasias. This patient was fitted with an Onefit scleral lens that provided good visual acuity and comfort. Lens handling was no obstacle to this patient. A heart surgery postponed the first follow-up examination. Follow-up examination 8 months after the refit resulted in no changes of lens parameters as the fitting was still acceptable and the patient was happy. Attention to the inferior limbal clearance will be the focus at the next follow-up in 6 months’ time.en_US
dc.language.isoengen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleRefitting a patient with pellucid marginal degeneration from a corneal rigid gas permeable lens to scleral lensen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© Copyright Lundanes, E., et al.en_US
dc.source.pagenumber19-23en_US
dc.source.volume13en_US
dc.source.journalScandinavian Journal of Optometry and Visual Scienceen_US
dc.source.issue1en_US
dc.identifier.doihttps://doi.org/10.5384/sjovs.vol13i1p19-23
dc.identifier.cristin2005198
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal